Portable Applications: Operating Modes
The CoolCube operates in 3 modes; FAN ONLY, DEHUMIDIFICATION, AND COOL. When in
FAN ONLY MODE the unit circulates the surrounding air. When in the DEHUMIDIFICATION
mode the unit will focus on removing moisture from the room. When in the COOL mode, the
compressor is engaged and cool air is circulated
Because individual applications vary, the CoolCube 10 allows the user to customize the unit with accessories
to meet the requirements of their particular environment. Choose from the following accessories or the
“Portable Package”:
• COOL Mode
The CoolCube will operate in FAN ONLY mode for approximately 90 seconds before the
compressor engages (compressor time delay program is 90 +/- 15 seconds).
Portable Accessories:
• Wheel Kit (Figure 1)
• Portable applications
• DEHUMIDIFCATION Mode
The CoolCube will operate in the COOL Mode for 10 minutes with the Low Speed Fan. Next the
CoolCube will operate in the FAN ONLY mode for 10 minutes with the Low Speed Fan. The
cycling will continue to repeat.
• Feet Kit (Figure 2)
• Semi-permanent applications
• Handle Kit (Figure 1 & 2)
• AUTO Fan Control
Automatic Speed will change the fan speed automatically by comparing the SET POINT with the
ROOM TEMP. When the ROOM TEMP is 10°F above the SET POINT, the unit will operate in
High Speed. When the ROOM TEMP is 6°F above the SET POINT, the unit will operate in
Medium Speed. Finally, when the ROOM TEMP is 4°F above the SET POINT, the unit will
operate in Low Speed.
• To facilitate moving and lifting the CoolCube 10 unit
Cold Air Distribution Accessories:
• Six-Inch Nozzle Kit (Figure 1)
• Concentrated short-range spot-cooling
• Temperature Control
The room temperature thermistor allows the unit to automatically switch between the COOL and
FAN ONLY modes. This is dependent upon inlet air temperature versus “SET POINT”
temperature.
• Diffuser Kit (Not Shown)
• Diffused spot-cooling
• Six-Inch Flange Kit (Figure 2)
• LOCK-IN Temperature Control
Lock-in a temperature SET POINT by pressing the UP & DOWN ARROW buttons simultaneously
for 3 seconds, a dot on the display will flash and illuminate when the temperature is fixed. To
unlock the temperature SET POINT press the UP & DOWN ARROW buttons simultaneously for 3
seconds, and the dot on the display will disappear.
• Allows ducting to be installed on the unit for long-range spot cooling requirements
Portable Package (See Figure 1):
• Wheel Kit
• Handle Kit
• TIMER Control
The TIMER Control turns the unit ON or OFF within a 12-hour period. If the unit is OFF press the
TIMER button until the desired hour ( 1 through 12) is set for the unit to TURN ON. If the unit is
ON, press the TIMER button until the desired hour (1 through 12) is set for the unit to TURN OFF.
Once the TIMER Control is set to turn ON or OFF the unit, the TIMER LED will illuminate.
• Six-Inch Nozzle Kit
• Sleep Control
The CoolCube can be operated by the SLEEP Control by pressing the SLEEP button, which
illuminates the LED. The SLEEP Control raises the SET POINT temperature by 1°F after the first
hour, then raises the SET POINT temperature by another 1°F after the second hour. After the
second hour, the SET POINT temperature will remain stable.
Attaching Accessories – (See Detailed Accessory Instructions)
• Attach the Portable Accessories (casters/feet) to the base panel of the CoolCube 10 unit.
See Figure 1 & 2
• Attach the Handles to the top panel of the CoolCube 10 unit. See Figure 1 & 2 (Optional)
• Fan Mode Control Dip Switch
The Fan Mode Control DIP Switch determines whether the FAN will continue to operate or stop
when the compressor cycles off. (“SET POINT” temperature equals inlet air or room temperature).
The unit has been preset at the factory for continuous fan operation.
• Attach the Cold Air Distribution Accessory (duct/diffuser/flange) to the front panel. See Figure 1 & 2